ASMi-450 Control from the Control Port
ASMi-450 Installation and Operation Manual
4-21
on the remote unit.
REMOTE UNIT
Displays the state of the loopback that can be
INITIATED LOOPS
activated by command from the remote
ASMi-450 unit on the local unit (this is REM
PORT, remote port loopback on the local unit,
toward the remote unit).
DSP ST SYS----------------------------------------------------------------------------------
Purpose
Display system status information.
Format
DSP ST SYS [option]
Use
To view the current system status, type:
DSP ST SYS
Display
Format
A typical status information display is shown below.
NODE
= 0
NAME
= 'ASMi-450 name'
NODAL CLOCK
= EXT
ASMI TYPE
= CNTR
NUM OF ACTIVE TS = 24
SOFTWARE REV
= X.Y
HARDWARE REV
= X.Y
The system status fields are described below (from top to bottom)
NODE
Displays the node number of the ASMi-450
NAME
Displays the node name of the ASMi-450
NODAL CLOCK
Indicates the current source for the ASMi-450 system clock:
INT or EXT (see Section 3-4).
NUM OF ACTIVE TS Indicates the number of active time slots configured on the
ASMi-450 (see Section 3-4).
ASMI TYPE
Indicates the function of the ASMi-450: central or remote.
SOFTWARE REV
Displays the ASMi-450 software version
HARDWARE REV
Displays the ASMi-450 hardware version
EXIT---------------------------------------------------------------------------------------------
Purpose
End the current session and return control to the ASMi-450 front panel.
Format
EXIT
Use
Type:
EXIT