ASMi-450 Control from the Control Port
ASMi-450 Installation and Operation Manual
4-17
Table 4-B. Control Terminal Alarm Messages
Alarm No.
Alarm Syntax
Meaning
State
Time
1
LOCAL DB
CHECKSUM ERROR
The data base currently stored in the non-
volatile memory of the local ASMi-450 is
corrupted. Message can appear only upon
power-up
[ON]
hh:mm:ss
2
LOCAL ALARM
BUFFER OVERFLOW
The alarm buffer of the local ASMi-450 is
full, and new alarms overwrite the older
alarms
[ON] [OFF]
hh:mm:ss
3
LOCAL SELF TEST
ERROR
A fault has been detected in the local
ASMi-450 during the power-up self-test
[ON]
hh:mm:ss
4
LOCAL HARDWARE
FAILURE
A hardware fault has been detected in the
local ASMi-450
[ON]
hh:mm:ss
5
LOCAL PSWRD
SWITCH IS ON
Section PSWD of switch S1 of the local
ASMi-450 is set to ON
[ON]
hh:mm:ss
6
LOCAL SP-PAR
SWITCH IS ON
Section DEF SP of switch S1 of the local
ASMi-450 is set to ON
[ON]
hh:mm:ss
7
LOCAL DB-INIT
SWITCH IS ON
Section DB INIT of switch S1 of the local
ASMi-450 is set to ON
[ON]
hh:mm:ss
8
LOCAL REAL TIME
CLOCK BATTERY
FAILURE
The battery that powers the local
ASMi-450 internal real-time clock when
ASMi-450 is not powered has failed
[ON]
hh:mm:ss
9
LOCAL REVERSE
POLARITY
Reversed loop polarity has been detected
by the local ASMi-450
[ON]
hh:mm:ss
10
LOCAL SIGNAL LOSS
Loss of HDSL line input signal at the local
ASMi-450
[ON] [OFF]
hh:mm:ss
11
LOCAL SYNC LOSS
The local ASMi-450 lost synchronization
to the HDSL line signal
[ON] [OFF]
hh:mm:ss
12
LOCAL LOW QUALITY
ALARM
The CRC-6 error rate detected on the
incoming HDSL signal exceeds 10-7
[ON]
hh:mm:ss
13
LOCAL TRANSMIT
SLIP
A slip has been detected on the local
transmit path
[ON]
hh:mm:ss
14
LOCAL RECEIVE SLIP
A slip has been detected on the local
receive path
[ON]
hh:mm:ss
15
LAN NOT CONNECTED No data is received from the user's port
(for ASMi-450 version with serial data
port).
or
The Ethernet interface is not connected to
an operating LAN (at least one station
must be active on the LAN)
[ON] [OFF]
hh:mm:ss