beautypg.com

Renesas RJJ10J1643-0101 User Manual

Page 99

background image

Rev.1.01 2007.02.16
RJJ10J1643-0101

97

(Count source) Specify one from { RAPI_TW_F1, RAPI_TW_F2, RAPI_TW_F4,

RAPI_TW_F8 }. The default value is RAPI_TW_F1.

(Operating

states set)

Specify one from { RAPI_TIMER_ON, RAPI_TIMER_OFF }. The default

value is RAPI_TIMER_OFF.

(Interrupt)

If overflow interrupt requests are enabled, specify RAPI_OVERFLOW. If no

interrupts are specified, “No interrupt request” is set.

• Specifiable definition values when timer Z is used (RAPI_TIMER_Z0 to

RAPI_TIMER_Z1 specified)

(Count source) Specify one from { RAPI_TZ_F1, RAPI_TZ_F2, RAPI_TZ_F4,

RAPI_TZ_F8 }. The default value is RAPI_TZ_F1.

(Operating

states set)

Specify one from { RAPI_TIMER_ON, RAPI_TIMER_OFF }. The default

value is RAPI_TIMER_OFF.

(Interrupt)

If overflow interrupt requests are enabled, specify RAPI_OVERFLOW. If no

interrupts are specified, “No interrupt request” is set.

(Input pin)

Specify one from { RAPI_FTIOA, RAPI_FTIOB }. The default value is

RAPI_FTIOA.

• Specifiable definition values when timer RC is used (RAPI_TIMER_RC specified)

(Count

source)

Specify one from { RAPI_TRC_F1, RAPI_TRC_F2, RAPI_TRC_F4,

RAPI_TRC_F8, RAPI_TRC_F32, RAPI_TRC_F40M }. The default value is

RAPI_RC_F1.

(Operating

states set)

Specify one from { RAPI_TIMER_ON, RAPI_TIMER_OFF }. The default

value is RAPI_TIMER_OFF.

(Interrupt)

If overflow interrupt requests are enabled, specify RAPI_OVERFLOW. If no

interrupts are specified, “No interrupt request” is set.

(Input pin)

Specify one from { RAPI_FTIOA, RAPI_FTIOB }. The default value is

RAPI_FTIOA.

(Clock for

digital filter)

Specify one from { RAPI_TRC_FILTER_F1, RAPI_TRC_FILTER_F8,

RAPI_TRC_FILTER_F32, RAPI_TRC_FILTER_F }. The default value is

RAPI_TRC_FILTER_F32.

• Specifiable definition values when timer RD is used (RAPI_TIMER_RD specified)

(Count

source)

Specify one from { RAPI_TRD_F1, RAPI_TRD_F2, RAPI_TRD_F4,

RAPI_TRD_F8, RAPI_TRD_F32, RAPI_TRD_F40M }. The default value is

RAPI_RC_F1.

(Operating

states set)

Specify one from { RAPI_TIMER_ON, RAPI_TIMER_OFF }. The default

value is RAPI_TIMER_OFF.

(Interrupt)

If overflow interrupt requests are enabled, specify RAPI_OVERFLOW. If no

interrupts are specified, “No interrupt request” is set.

(Input pin)

Specify one from { RAPI_FTIOA, RAPI_FTIOB }. The default value is

RAPI_FTIOA.

(Clock for

digital filter)

Specify one from { RAPI_TRC_FILTER_F1, RAPI_TRC_FILTER_F8,

RAPI_TRC_FILTER_F32, RAPI_TRC_FILTER_F }. The default value is

RAPI_TRC_FILTER_F32.

[data2]