beautypg.com

Renesas RJJ10J1643-0101 User Manual

Page 26

background image

Rev.1.01 2007.02.16
RJJ10J1643-0101

24

__BasicSetSerialFormat

Synopsis

Boolean __BasicSetSerialFormat(unsigned long data1, unsigned char data2)

data1

Setup data 1

data2

Setup data 2

Description

Sets serial communication according to specified parameters.

[data1]

For data1, the following values can be set. To set multiple definition values at the same
time, use the symbol “|” to separate each specified value.

(M16C)

RAPI_COM1 UART0

RAPI_COM2 UART1

RAPI_COM3 UART2

RAPI_COM4 SI/O3

RAPI_COM5 SI/O4

For serial communication mode, the following values can be set.

(M16C) (UART0, UART1, UART2)

RAPI_SM_SYNC

Clock synchronous serial communication mode

RAPI_SM_ASYNC

Clock asynchronous serial communication mode

(M16C)(SI/O3, SI/O4)

RAPI_SIO_SM_SYNC

Clock synchronous serial communication mode

For the data length format of clock asynchronous serial communication, the following
values can be set.

If the API is used in clock synchronous serial communication mode, do not set these
values.

(M16C) (UART0, UART1, UART2)

RAPI_BIT_7

Transfer data length 7 bits

RAPI_BIT_8

Transfer data length 8 bits

RAPI_BIT_9

Transfer data length 9 bits

For the clock source of serial communication, the following values can be set.

(M16C) (UART0, UART1, UART2)

RAPI_CKDIR_INT

Internal clock is used as the clock source of serial communication.

RAPI_CKDIR_EXT

External clock is used as the clock source of serial communication.

(M16C) (SI/O3, SI/O4)

RAPI_SIO_CKDIR_INT

Internal clock is used as the clock source of serial communication.

RAPI_SIO_CKDIR_EXT

External clock is used as the clock source of serial communication.

For the stop bit length of clock asynchronous serial communication, the following
values can be set.

If the API is used in clock synchronous serial communication mode, do not set these
values.

(M16C) (UART0, UART1, UART2)

RAPI_STPB_1

1 stop bit

RAPI_STPB_2

2 stop bits

For the parity bit of clock asynchronous serial communication, the following values can
be set.