__StartSerialSending
Synopsis
transmission> Boolean __StartSerialSending(unsigned long data, unsigned char wordNum, unsigned int *SndDtBuf) data Setup data wordNum Number of words transmitted SndDtBuf Pointer to the transmit data Description Starts transmission of serial communication and writes transmit data to the transmit [data] For data, the following values can be set. (M16C) RAPI_COM1 UART0 RAPI_COM2 UART1 RAPI_COM3 UART2 RAPI_COM4 SI/O3 RAPI_COM5 SI/O4 (R8C) RAPI_COM1 UART0 RAPI_COM2 UART1 (H8/300H) RAPI_COM1 SCI3 channel 1 RAPI_COM2 SCI3 channel 2 RAPI_COM3 SCI3 channel 3 Return value If transmission of serial communication was successfully started, RAPI_TRUE is Functionality Serial I/O Reference __ConfigSerialDriverNotify , __StopSerialSending Remark • For the H8/300H, wait for at least a 1-bit period before calling this API after • The specifiable serial ports differ with each CPU used. • If an undefined value is specified in the first argument, operation of the API cannot be guaranteed. Program example #include ”rapi_sif_r8c_13.h”
buffer by a specified number of words. When transmission of all transmit data is
complete, this API calls a notification function (if a notification function is registered).
returned; if failed, RAPI_FALSE is returned.
__SetSerialFormat was called.