beautypg.com

Renesas RJJ10J1643-0101 User Manual

Page 143

background image

Rev.1.01 2007.02.16
RJJ10J1643-0101

141

[3]: Specify the set value for timer control register V0.

[4]: Specify the set value for timer control register V1.

[5]: Specify the set value for timer control/status register V.

• When using timer W (RAPI_TIMER_W specified)

[0]: Specify the set value for timer control register W.

[1]: Specify the set value for timer interrupt enable register W.

[2]: Specify the set value for timer status register W.

[3]: Specify the set value for timer I/O control register 0.

[4]: Specify the set value for timer I/O control register 1.

[5]: Specify the set value for the timer counter.

[6]: Specify the set value for general register A.

[7]: Specify the set value for general register B.

[8]: Specify the set value for general register C.

[9]: Specify the set value for general register D.

[10]: Specify the set value for the timer mode register W.

• When using timer Z (RAPI_TIMER_Z0 to RAPI_TIMER_Z1 specified)

[0]: Specify the set value for the timer mode register.

[1]: Specify the set value for the timer PWM mode register.

[2]: Specify the set value for the timer function control register.

[3]: Specify the set value for the timer output master enable register.

[4]: Specify the set value for the timer output control register.

[5]: Specify the set value for the timer counter.

[6]: Specify the set value for general register A i(i=0,1).

[7]: Specify the set value for general register B i(i=0,1).

[8]: Specify the set value for general register C i(i=0,1).

[9]: Specify the set value for general register D i(i=0,1).

[10]: Specify the set value for timer control register_i (i = 0, 1).

[11]: Specify the set value for timer I/O control register A_i (i = 0, 1).

[12]: Specify the set value for timer I/O control register C_i (i = 0, 1).

[13]: Specify the set value for timer status register_i (i = 0, 1).

[14]: Specify the set value for timer interrupt enable register_i (i = 0, 1).

[15]: Specify the set value for PWM mode output level control register_i (i = 0, 1).

[16]: Specify the set value for the timer start register.

• When using timer RC (RAPI_TIMER_RC)

[0]: Specify the set value for timer RC control register 1.

[1]: Specify the set value for timer RC control register 2.

[2]: Specify the set value for timer RC interrupt enable register.

[3]: Specify the set value for timer RC status register.

[4]: Specify the set value for timer RC I/O control register 0.

[5]: Specify the set value for timer RC I/O control register 1.

[6]: Specify the set value for timer RC output enable register.

[7]: Specify the set value for timer RC digital filter function select register.

[8]: Specify the set value for timer RC counter.

[9]: Specify the set value for general register A.

[10]: Specify the set value for general register B.