beautypg.com

Renesas RJJ10J1643-0101 User Manual

Page 37

background image

Rev.1.01 2007.02.16
RJJ10J1643-0101

35

__BasicStopSerialSending

Synopsis

transmission>

Boolean __BasicStopSerialSending(unsigned long data)

data Setup

data

Description

Stops transmitting data in serial communication.

[data]

For data, the following values can be set.

(M16C)

RAPI_COM1 UART0

RAPI_COM2 UART1

RAPI_COM3 UART2

(R8C)

RAPI_COM1 UART0

RAPI_COM2 UART1

(H8/300H)

RAPI_COM1

SCI3 channel 1

RAPI_COM2

SCI3 channel 2

SIO3_COM3

SIO3 channel 3

Return value

If data transmission in serial communication was successfully stopped, RAPI_TRUE is
returned; if failed, RAPI_FALSE is returned.

Functionality

Serial

I/O

Reference

__BasicStartSerialSending

Remark

For the M16C SI/03 and SI/04, this API cannot be used.

The specifiable serial ports differ with each CPU used.

When operating in clock synchronous serial communication mode, data reception is

stopped at the same time by this API.

If an undefined value is specified in the argument, operation of the API cannot be

guaranteed.

Program example

#include ”rapi_sif_r8c_13.h”

void func( void )
{
………………
/* Stop sending data in serial communication */
__BasicStopSerialSending ( RAPI_COM1 );
………………
}