__BasicStopSerialSending
Synopsis
transmission> Boolean __BasicStopSerialSending(unsigned long data) data Setup data Description Stops transmitting data in serial communication. [data] For data, the following values can be set. (M16C) RAPI_COM1 UART0 RAPI_COM2 UART1 RAPI_COM3 UART2 (R8C) RAPI_COM1 UART0 RAPI_COM2 UART1 (H8/300H) RAPI_COM1 SCI3 channel 1 RAPI_COM2 SCI3 channel 2 SIO3_COM3 SIO3 channel 3 Return value If data transmission in serial communication was successfully stopped, RAPI_TRUE is Functionality Serial I/O Reference __BasicStartSerialSending Remark • For the M16C SI/03 and SI/04, this API cannot be used. • The specifiable serial ports differ with each CPU used. • When operating in clock synchronous serial communication mode, data reception is stopped at the same time by this API. • If an undefined value is specified in the argument, operation of the API cannot be guaranteed. Program example #include ”rapi_sif_r8c_13.h” void func( void )
returned; if failed, RAPI_FALSE is returned.
{
………………
/* Stop sending data in serial communication */
__BasicStopSerialSending ( RAPI_COM1 );
………………
}