beautypg.com

Renesas RJJ10J1643-0101 User Manual

Page 122

background image

Rev.1.01 2007.02.16
RJJ10J1643-0101

120

• When timer RD is used (RAPI_TIMER_RD0- RAPI_TIMER_RD1 specified)

[0]: Stores the value of timer counter.

[1]: Stores the value of general register A.

[2]: Stores the value of general register B.

[3]: Stores the value of general register C.

[4]: Stores the value of general register D.

(H8/300H)

[0]: Stores the value of the timer counter.

[1]: Stores the value of general register A.

[2]: Stores the value of general register B.

[3]: Stores the value of general register C.

[4]: Stores the value of general register D.

Return value

If the timer specification is incorrect, RAPI_FALSE is returned; otherwise, RAPI_TRUE
is returned.

Functionality

Timer (input capture mode)

Reference

__CreateInputCapture

,

__EnableInputCapture

,

__DestroyInputCapture

Remark

If an undefined value is specified in the first argument, operation of the API cannot
be guaranteed.

The specifiable timers differ with each CPU used.

Program example

#include "rapi_timer_r8c_13.h"

void func( void )
{
unsigned int data[2];

/* Get the counter of timer C as input capture mode */
__GetInputCapture( RAPI_TIMER_C, data );
}