RJJ10J1643-0101

109

(Counter

clear)

To specify GRA, GRB, GRC, or GRD input capture for the cause for which

the counter is cleared, select RAPI_COUNT_CLEAR_A,

RAPI_COUNT_CLEAR_B, RAPI_COUNT_CLEAR_C, or

RAPI_COUNT_CLEAR_D, respectively. If cleared at the same time a

synchronously operating counter on another channel is cleared, select

RAPI_COUNT_CLEAR_SYNC.

• Specifiable definition values when timer Z is used (RAPI_TIMER_Z0 to

RAPI_TIMER_Z1 specified)

(Count source)

Specify one from { RAPI_TZ_F1, RAPI_TZ_F2, RAPI_TZ_F4,

RAPI_TZ_F8 }. The default value is RAPI_TZ_F1.

(Operating

states set)

Specify one from { RAPI_TIMER_ON, RAPI_TIMER_OFF }. The default

value is RAPI_TIMER_OFF.

(Interrupt)

If overflow interrupt requests are enabled, specify RAPI_OVERFLOW.

Similarly, if input capture A, input capture B, input capture C, or input

capture D interrupt requests are enabled, specify

RAPI_INPUT_CAPTURE_A, RAPI_INPUT_CAPTURE_B,

RAPI_INPUT_CAPTURE_C, or RAPI_INPUT_CAPTURE_D,

respectively. If no interrupts are specified, “No interrupt request” is set.

(Counter clear)

To specify GRA, GRB, GRC, or GRD input capture for the cause of

counter clear, specify RAPI_COUNT_CLEAR_A,

RAPI_COUNT_CLEAR_B, RAPI_COUNT_CLEAR_C, or

RAPI_COUNT_CLEAR_D, respectively.

(Synchronization) If the timer is synchronized on channels 0 and 1, specify

RAPI_TIMER_SYNC. If synchronization is not specified, “Channels 0 and

1 operate independently” is set.

• Specifiable definition values when timer RC is used (RAPI_TIMER_RC specified)

(Count

source)

Specify one from [RAPI_TRD_F1, RAPI_TRD_F2, RAPI_TRD_F4,

RAPI_TRD_F8, RAPI_TRD_F32, RAPI_TRD_F40M]. The default is

RAPI_TRD_F1.

(Operating

states set)

Specify one from [RAPI_TIMER_ON, RAPI_TIMER_OFF]. The default is

RAPI_TIMER_OFF.

(Interrupt)

If overflow interrupt requests are enabled, specify RAPI_OVERFLOW. If

input capture A, input capture B, input capture C, or input capture D

interrupt requests are enabled, specify RAPI_INPUT_CAPURE_A,

RAPI_INPUT_CAPURE_B, RAPI_INPUT_CAPURE_C, or

RAPI_INPUT_CAPURE_D, respectively. When not specifying interrupts,

select “No interrupt requests.”

(Clock for digital

filter)

Specify one from [RAPI_TRD_FILTER_F1, RAPI_TRD_FILTER_F8,

RAPI_TRD_FILTER_F32, RAPI_TRD_FILTER_F]. The default is

RAPI_TRD_FILTER_F32.

• Specifiable definition values when timer RD is used (RAPI_TIMER_RD specified)

(Count

source)

Specify one from [RAPI_TRD_F1, RAPI_TRD_F2, RAPI_TRD_F4,

RAPI_TRD_F8, RAPI_TRD_F32, RAPI_TRD_F40M]. The default is

RAPI_TRD_F1.