Rev.1.01 2007.02.16
RJJ10J1643-0101

124

(TC reload)

To reload TC register, specify RAPID_RELOAD. If RAPID_RELOAD is

not specified, “No reload” is set.

(CMP0 output

mode)

Specify one from { RAPI_UNCHANGE_0, RAPI_REVERSE_0,

RAPI_L_0, RAPI_H_0 }. The default value is RAPI_UNCHANGE_0.

(CMP1 output

mode)

Specify one from { RAPI_UNCHANGE_1, RAPI_REVERSE_1,

RAPI_L_1, RAPI_H_1 }. The default value is RAPI_UNCHANGE_1.

• Specifiable definition values when timer RD is used (RAPI_TIMER_RD specified)

(Count source)

Specify one from [RAPI_TRD_F1, RAPI_TRD_F2, RAPI_TRD_F4,

RAPI_TRD_F8, RAPI_TRD_F32, RAPI_TRD_F40M]. The default is

RAPI_TRD_F1.

(Operating states

set)

Specify one from [RAPI_TIMER_ON, RAPI_TIMER_OFF]. The default

is RAPI_TIMER_OFF

(Interrupt)

If overflow interrupt requests are enabled, specify RAPI_OVERFLOW.

If input capture A, input capture B, input capture C, or input capture D

interrupt requests are enabled, specify RAPI_INPUT_CAPURE_A,

RAPI_INPUT_CAPURE_B, RAPI_INPUT_CAPURE_C, or

RAPI_INPUT_CAPURE_D, respectively. When not specifying

interrupts, select “No interrupt requests.”

(Counter clear)

To specify GRA, GRB, GRC, or GRD input capture for the cause for

which the counter is cleared, select RAPI_COUNT_CLEAR_A,

RAPI_COUNT_CLEAR_B, RAPI_COUNT_CLEAR_C, or

RAPI_COUNT_CLEAR_D, respectively. If cleared at the same time a

synchronously operating counter on another channel is cleared, select

RAPI_COUNT_CLEAR_SYNC.

(Synchronization)

If timers on channels 0 and 1 are to be synchronized, select

RAPI_TIMER_SYNC. When not specifying synchronization, select

“Channels 0 and 1 operate independently.”

(count stop)

Specify one from [RAPI_COMPARE_MATCH_A_STOP, RAPI_STOP].

The default is RAPI_STOP.

• Specifiable definition values when timer RE is used (RAPI_TIMER_RE specified)

(Count source)

Specify one from [RAPI_TRE_F4, RAPI_TRE_F8, RAPI_TRE_F32,

RAPI_TRD_FC4]. The default is RAPI_TRD_F1.

(Operating states

set)

Specify one from [RAPI_TIMER_ON, RAPI_TIMER_OFF]. The default

is RAPI_TIMER_OFF

(Interrupt)

If compare match interrupt requests are enabled, specify

RAPI_COMPARE_MATCH. When not specifying interrupts, select “No

interrupt requests.”

(Output function)

Specify one from [RAPI_OUTPUT_DISABLE, RAPI_OUTPUT_F2,

RAPI_OUTPUT_F4, RAPI_OUTPUT_F8,

RAPI_OUTPUT_COMPARE]. The default is

RAPI_OUTPUT_COMPARE.

(Counter)

If use 4 bit counter, spcify RAPI_4BIT_COUNTER. The default is 8 bit

counter .

(H8/300H)