beautypg.com

Renesas RJJ10J1643-0101 User Manual

Page 103

background image

Rev.1.01 2007.02.16
RJJ10J1643-0101

101

__DestroyPulseWidthMeasurementMode

Synopsis

Boolean __DestroyPulseWidthMeasurementMode(unsigned long data)

data

Setup data (content differs with MCU type)

Description

Discards settings of the timer that is set to specified pulse width measurement mode.

[data]

For data, the following definition values can be set.

(M16C)

RAPI_TIMER_B0

Selects timer B channel 0.

RAPI_TIMER_B1

Selects timer B channel 1.

RAPI_TIMER_B2

Selects timer B channel 2.

(R8C)

RAPI_TIMER_X

Selects timer X.

(H8/300H)

RAPI_TIMER_W

Selects timer W.

RAPI_TIMER_Z0

Selects timer Z channel 0.

RAPI_TIMER_Z1

Selects timer Z channel 1.

RAPI_TIMER_RC

Selects timer RC.

RAPI_TIMER_RD

0

Selects timer RD channel 0.

RAPI_TIMER_RD

1

Selects timer RD channel 1.

RAPI_TIMER_RD

2

Selects timer RD channel 2.

RAPI_TIMER_RD

3

Selects timer RD channel 3.

Return value

If the timer specification is incorrect, RAPI_FALSE is returned; otherwise, RAPI_TRUE
is returned.

Functionality

Timer (pulse width measurement mode)

Reference

__CreatePulseWidthMeasurementMode

,

__EnablePulseWidthMeasurementMode

,

__GetPulseWidthMeasurementMode

Remark

If an undefined value is specified in the argument, operation of the API cannot be
guaranteed.

The specifiable timers differ with each CPU used.

When used for the H8/300H, this API places a specified timer into module stanby
state after discarding it.