RJJ10J1643-0101

108

RAPI_TRD_F4

Timer RD counts with internal clockφ/4.

RAPI_TRD_F8

Timer RD counts with internal clock φ/8.

RAPI_TRD_F32

Timer RD counts with internal clock φ/32.

RAPI_TRD_F40M

Timer RD counts with internal clock φ40M.

RAPI_TIMER_ON

Sets the timer to start operating in __CreateInputCapture.

RAPI_TIMER_OFF

Sets the timer to stop operating in __CreateInputCapture.

RAPI_OVERFLOW

Enables overflow interrupt.

RAPI_INPUT_

CAPTURE_A

Enables GRA input capture interrupt.

RAPI_INPUT_

CAPTURE_B

Enables GRB input capture interrupt.

RAPI_INPUT_

CAPTURE_C

Enables GRC input capture interrupt.

RAPI_INPUT_

CAPTURE_D

Enables GRD input capture interrupt.

RAPI_COUNT_CLEAR_A

Specifies GRA input capture for the cause of counter clear.

RAPI_COUNT_CLEAR_B

Specifies GRB input capture for the cause of counter clear.

RAPI_COUNT_CLEAR_C

Specifies GRC input capture for the cause of counter clear.

RAPI_COUNT_CLEAR_D

Specifies GRD input capture for the cause of counter clear.

RAPI_COUNT_CLEAR_S

YNC

Clear counter in sync with the synchronized other timer counter

RAPI_TIMER_SYNC

Synchronizes timer on channels 0 and 1.

RAPI_TRC_FILTER_F1

Use sampling frequency f1 for timer RC digital filter function

RAPI_TRC_FILTER_F8

Use sampling frequency f8 for timer RC digital filter function

RAPI_TRC_FILTER_F32

Use sampling frequency f32 for timer RC digital filter function

RAPI_TRC_FILTER_F

Use sampling frequency f for timer RD digital filter function

RAPI_TRD_FILTER_F1

Use sampling frequency f1 for timer RD digital filter function

RAPI_TRD_FILTER_F8

Use sampling frequency f8 for timer RD digital filter function

RAPI_TRD_FILTER_F32

Use sampling frequency f32 for timer RD digital filter function

RAPI_TRD_FILTER_F

Use sampling frequency f for timer RD digital filter function

• Specifiable definition values when timer W is used (RAPI_TIMER_W specified)

(Count source) Specify one from { RAPI_TW_F1, RAPI_TW_F2, RAPI_TW_F4,

RAPI_TW_F8 }. The default value is RAPI_TW_F1.

(Operating

states set)

Specify one from { RAPI_TIMER_ON, RAPI_TIMER_OFF }. The default

value is RAPI_TIMER_OFF.

(Interrupt)

If overflow interrupt requests are enabled, specify RAPI_OVERFLOW.

Similarly, if input capture A, input capture B, input capture C, or input capture

D interrupt requests are enabled, specify RAPI_INPUT_CAPTURE_A,

RAPI_INPUT_CAPTURE_B, RAPI_INPUT_CAPTURE_C, or

RAPI_INPUT_CAPTURE_D, respectively. If no interrupts are specified, “No

interrupt request” is set.