RAPI_WRITE_

RELOAD_ BOTH

Selects operation mode in which writing to the primary register and

prescaler causes the set data to be written to both the reload

register and the counter, respectively.

RAPI_RISING

Selects the rising edge of count source as active edge.

RAPI_FALLING

Selects the falling edge of count source as active edge.

RAPI_FILTER_F1

Use sampling frequency f1 for digital filter function

RAPI_FILTER_F8

Use sampling frequency f8 for digital filter function

RAPI_FILTER_F32

Use sampling frequency f32 for digital filter function

RAPI_TIOSEL_P1_7

Sets count source input pin to P1_7.

RAPI_TIOSEL_P1_5

Sets count source input pin to P1_5.

RAPI_PULSE_ON

Selects that pulses are output from TRA0 pin.

RAPI_PULSE_OFF

Selects that no pulses are output from TRA0 pin.

• Specifiable definition values when timer X is used (RAPI_TIMER_X specified)

(Operating

states set)

Specify one from { RAPI_TIMER_ON, RAPI_TIMER_OFF }. The default

value is RAPI_TIMER_OFF.

(Count edge)

Specify one from { RAPI_RISING, RAPI_FALLING }. The default value is

RAPI_FALLING.

• Specifiable definition values when timer Y is used (RAPI_TIMER_Y specified)

(Operating

states set)

Specify one from { RAPI_TIMER_ON, RAPI_TIMER_OFF }. The default

value is RAPI_TIMER_OFF.

(Write control)

Specify one from { RAPI_WRITE_RELOAD_ONLY,

RAPI_WRITE_RELOAD_BOTH }.

The default value is RAPI_WRITE_RELOAD_BOTH.

(INT2/CNTR1

input)

Specify one from { RAPI_RISING, RAPI_FALLING }. The default value is

RAPI_FALLING.

• Specifiable definition values when timer RA is used (RAPI_TIMER_RA specified)

(Operating

states set)

Specify one from { RAPI_TIMER_ON, RAPI_TIMER_OFF }. The default

value is RAPI_TIMER_OFF.

(Count edge)

Specify one from { RAPI_RISING, RAPI_FALLING }. The default value is

RAPI_FALLING.

(Filter)

Specify one from { RAPI_FILTER_F1, RAPI_FILTER_F8,

RAPI_FILTER_F32}. The default value is no filter.

(Input pin)

Specify one from { RAPI_TIOSEL_P1_7, RAPI_TIOSEL_P1_5 }. The

default value is RAPI_TIOSEL_P1_7.

(Pulse output

function)

Specify one from { RAPI_PULSE_ON, RAPI_PULSE_OFF }. The default

value is RAPI_PULSE_OFF.

(H8/300H)

RAPI_TIMER_B1

Uses timer B1.

RAPI_TIMER_V

Uses timer V.

RAPI_TIMER_ON

Sets the timer to start operating in __CreateEventCounter.

RAPI_TIMER_OFF

Sets the timer to stop operating in __CreateEventCounter.

RAPI_OVERFLOW

Enables overflow interrupt.

RAPI_AUTO_RELOAD

Uses auto reload facility.