beautypg.com

Renesas RJJ10J1643-0101 User Manual

Page 78

background image

Rev.1.01 2007.02.16
RJJ10J1643-0101

76

RAPI_RISING

Selects the rising edge of TA

iIN

pin input signal as active edge.

RAPI_FALLING

Selects the falling edge of TA

iIN

pin input signal as active edge.

• Specifiable definition values when timer A is used (RAPI_TIMER_A0 to

RAPI_TIMER_A4 specified)

(Count source)

Specify one from { RAPI_F1, RAPI_F2, RAPI_F32, RAPI_FC32 }.

The default value is RAPI_F2.

(Operating states set) Specify one from { RAPI_TIMER_ON, RAPI_TIMER_OFF }. The

default value is RAPI_TIMER_OFF.

(Count start condition) Specify one from { RAPI_TG_TAIS, RAPI_TG_TAIIN,

RAPI_EV_TIMER_AJ, RAPI_EV_TIMER_AK,

RAPI_EV_TIMER_B2 }. The default value is RAPI_TG_TAIIN.

(Pulse output facility)

Specify one from { RAPI_PULSE_ON, RAPI_PULSE_OFF }. The

default value is RAPI_PULSE_OFF.

(Modulator)

Specify one from { RAPI_PWM_16, RAPI_PWM_8 }. The default

value is RAPI_PWM_16.

(TA

iIN

pin input)

Specify one from { RAPI_RISING, RAPI_FALLING }. The default

value is RAPI_FALLING. The active edge of TA

iIN

pin input can only

be set when RAPI_TG_TAIIN is selected.

(R8C)

RAPI_TIMER_Y Uses

timer

Y.

RAPI_TIMER_Z

Uses timer Z.

RAPI_TIMER_RB

Uses timer RB.

RAPI_F1 Selects

f

1

for the count source.

RAPI_F2 Selects

f

2

for the count source.

RAPI_F8 Selects

f

8

for the count source.

RAPI_FRING Selects

f

RING

for the count source.

RAPI_TIMER_Y_

UNDERFLOW

Selects underflow of timer Y for the count source.

RAPI_TIMER_RA_

UNDERFLOW

Selects underflow of timer RA for the count source.

RAPI_TIMER_ON

Sets the timer to start operating in __CreatePulseWidthModulationMode.

RAPI_TIMER_OFF

Sets the timer to stop operating in __CreatePulseWidthModulationMode.

RAPI_H_L_L

Sets to output a high during the primary period, a low during the

secondary period, and a low when the timer is idle.

RAPI_L_H_H

Sets to output a low during the primary period, a high during the

secondary period, and a high when the timer is idle.

• Specifiable definition values when timer Y is used (RAPI_TIMER_Y specified)

(Count source)

Specify one from { RAPI_F1, RAPI_F8, RAPI_FRING }. The default

value is RAPI_F1.

(Operating states set) Specify one from { RAPI_TIMER_ON, RAPI_TIMER_OFF }. The

default value is RAPI_TIMER_OFF.

(Output)

Specify one from { RAPI_H_L_L, RAPI_L_H_H }. The default value is

RAPI_H_L_L.

• Specifiable definition values when timer Z is used (RAPI_TIMER_Z specified)