Delayed trigger mode 1

Repeat sweep mode

Specify 1, 2, 3, or 4.

(R8C)

Specify 1.

(H8/300H)

One-shot mode

Specify 1.

Repeat mode

Single sweep mode

Specify 1, 2, 3, or 4.

Repeat sweep mode 0

[data3]

(M16C) (R8C)

Specify the interrupt priority level (0–7) to be set in the interrupt control register.

(H8/300H)

Specify the interrupt priority level (0–1) to be set in the interrupt control register.
For the CPUs that do not have an interrupt control register, specify 0.

Return value

If A/D converter was successfully set, RAPI_TRUE is returned; if failed, RAPI_FALSE
is returned.

Functionality

A/D converter

Reference

__EnableADC

,

__DestroyADC

,

__GetADC

,

__GetADCAll

Remark

If an undefined value is specified in the first argument, operation of the API cannot
be guaranteed.

The specifiable analog input pins differ with each CPU used.

If you use an R8C MCU which does not support fOCO-F for its operating frequency, you

cannot specify RAPI_FOCOF.

If you use an R8C MCU which does not support timer RD as a trigger, you cannot specify

RAPI_TIMER_RD_TRIGGER as a trigger.

When used for the H8/300H, this API specify when freeing it from module stanby.

Program example

#include " rapi_ad_r8c_13.h"

void AdIntFunc( void ){}

void func( void )
{
/* Set up A/D converter as one short mode */
__CreateADC( RAPI_ONE_SHOT|RAPI_AN2|RAPI_FAD2| RAPI_WITH_SAMPLE_HOLD
|
RAPI_EXTERNAL_TRIGGER

|RAPI_AD_ON|RAPI_10BIT,

1,

5,

AdIntFunc );
}