beautypg.com

Printronix Network Interface Card User Manual

Page 327

background image

Set Commands

327

set model config [config_num]

Set a printer configuration number config_num to be loaded
prior to printing a job on the specified model. If the command is
sent with config_num set to 0, the factory configuration is
loaded before the job prints. If config_num is in the range 1
through 8, the corresponding configuration number is loaded
before the job prints. To return to the default state where no
configuration is loaded, send the command with no config_num
value; for example ‘set model m1 config’. When no new
configuration is loaded, the current configuration settings will
be in effect for any jobs sent to model . To see which
configuration, if any, will be loaded at the start of a job, use the
command ‘list model’ or ‘list model ’.

set model from default

Set all model settings back to factory defaults.

set model from stored

Set all current model settings to the values stored in flash
memory.

set prn [-]autofd

Example: set prn -autofd

Assert or do not assert the AUTOFD line for carriage return
insertion. This only affects printers that support this function,
such as impact printers.

set prn flush

Flush the data in the parallel port input and output buffers.

set prn unlock

Release the access lock on the parallel port.

set prn timeout |none

Example: set prn timeout none

Terminate the print job sent to the parallel port if it is not printed
after the timeout period in minutes () expires. The
value ranges from 0 though 255, with 0 indicating no timing out
to take place. This is the default setting and should be fine for
most print setups.