Run and auto reset modes, Network indicator – Printronix Network Interface Card User Manual
Page 25
10/100Base-T
25
Run and Auto Reset Modes
Run mode is the normal operating state of the NIC. Auto Reset
mode is entered when the watchdog timer is triggered and the Print
Server resets itself. In either mode, the STAT LED flashes at a
varying rate, depending on whether the unit IP address is
configured. The Run Mode and Auto Reset Mode indicator
descriptions are given in Table 1.
Network Indicator
The NET LED displays the status of the network link. When the
NET LED is on, link integrity is confirmed. The NET LED flashes off
for 1/3 second when a data packet is being transferred. When the
NET LED is off, the network connection has been severed.
Table 1. Run Mode and Auto Reset Mode Indicator Descriptions
STAT
Indication
Description
OFF
flashes on once per second
Normal Mode, IP address configured
OFF
flashes on two times per
second
IP address not configured
ON
flashes off once per second
Download (MOS)
ON
flashes off twice per second
Error
Table 2. NET LED Indicator
NET
Indication
Description
ON
constantly
Indicates link integrity
ON
flashes off 1/3 second
Flashes off 1/3 second each time a