2. BitStorm 1900 Installation and Testing

2-64

BitStorm 1900 Installation and Maintenance Guide

1900-A2-GN20-00

Task 009: Installing Voice/Data w/Filter 66-Block

Connections

Use this procedure to connect the BitStorm 1900 to the EtherLoop
cross-connect in applications where voice/data service is required with
a Filter 66-Block.

Requirements

This procedure requires the following tools and materials:

5 BitStorm 1900 cable harnesses

5 intermediate cables

Cross-connect block(s) of the same type used in the existing main
distribution frame (MDF)

Cross-connect punch-down tool

Jumper Wire (24 AWG)

"Appendix B. Cabling Specifications," on page 115 contains the
complete specifications for the cables and wiring required in this
procedure.

Step

Procedure

1.)

Mount 66-blocks on wall in an appropriate area for running

jumpers.

2.)

Verify the room position on frame blocks.

3.)

Replace jumpers to 66-Filter Block and retest phone lines.

4.)

Refer to Figure 2-14, "Voice/Data Filter 66-Block Connections for

10306 CO Modems," on page 65, and Figure 2-15, "Voice/Data
Filter 66-Block Connections for 10224 CO Modems," on page 66
.