2. BitStorm 1900 Installation and Testing

2-60

BitStorm 1900 Installation and Maintenance Guide

1900-A2-GN20-00

Step

Procedure

(continued)

4.)

Connect one Amp-Champ connector of an intermediate cable to

the "Line/CPE" side of the EtherLoop cross-connect block, then
connect the other end to an Amp-Champ to Dual Omni Grid cable.

5.)

Connect the Amp-Champ connector of the second intermediate

cable to the "Voice" side of the EtherLoop cross-connect block,
then connect the other end to an Amp-Champ to Dual Omni Grid
cable.

6.)

Connect the two Omni-Grid connectors from the EtherLoop "Line/

CPE" side to the "Dial Tone & EtherLoop OUT" ports of the filter
shelf as shown in Figure 2-12, "Line/CPE and Voice Connections
on the Filter Shelf for 10306 Modem Cards," on page 61
.

7.)

Connect the two Omni-Grid connectors from the "Voice" side to the

"Dial Tone IN from PBX/PSTN" ports of the filter shelf as shown in
Figure 2-12, "Line/CPE and Voice Connections on the Filter Shelf
for 10306 Modem Cards," on page 61
, a
nd Figure 2-13, "Line/CPE
and Voice Connections on the Filter Shelf for 10224 Modem
Cards," on page 62
. Record EtherLoop assignments.