beautypg.com

X parameters -193 – PIONEERPOS AT Commands G24-LC User Manual

Page 257

background image

Chapter 3: AT Commands Reference

April 15, 2008

G24-L AT Commands Reference Manual

3-193

Example

ATE?

001

OK

X, Result Code Selection and Call Progress Monitoring Control

This command defines the CONNECT result code format. It determines whether or not the
G24-L transmits particular result codes to the user. It also controls whether the G24-L verifies the
presence of dial tone when it first goes off-hook to begin dialing, and whether the engaged tone
(busy signal) detection is enabled.

The following table shows the X parameters.

Example

ATX?

000

OK

Command Type

Syntax

Response/Action

Remarks

Set

ATX

OK

or:

+CME ERROR:

The Set command sets the result code
and call progress monitoring control.

Read

ATX?

Test

The Test command for X is not defined
by ITU, and therefore is not supported
by the G24-L. The G24-L returns an
error.

Table 3-130: X Parameters

Description

0

CONNECT result code given upon entering online data state:
Dial tone detection - Disabled
Busy detection - Disabled

1

CONNECT result code given upon entering online data state:
Dial tone detection - Disabled
Busy detection - Disabled

2

CONNECT result code given upon entering online data state:
Dial tone detection - Enabled
Busy detection - Disabled

3

CONNECT result code given upon entering online data state:
Dial tone detection - Disabled
Busy detection - Enabled

4

CONNECT result code given upon entering online data state:
Dial tone detection - Enabled
Busy detection - Enabled

The default value is 0.

This manual is related to the following products: