+CBAUD, Baud Rate Regulation
This command sets the baud rate. The baud rate of the G24-L is changed/set to the request value
Specifying a value of 9 or 0 disables the function and allows operation only at rates automatically
detectable by the G24-L. The specified rate takes effect following the issuing of any result
code(s) associated with the current command line.
The UART is configured according to the request, or to the specific constant baud rate or auto
baud rate after output "OK" response to the terminal. For example, AT+CBAUD=8 is equivalent
to AT+CBAUD=57600. Using AT+CBAUD with the
auto baud rate detection feature.
The following table shows the +CBAUD parameters.
Example
AT+CBAUD=57600
or
AT+CBAUD=8
//These commands have the same effect
OK
Command Type
Syntax
Response/Action
Set
AT+CBAUD=
AT+CBAUD=
OK
or:
ERROR
Read
AT+CBAUD?
+CBAUD:
Test
AT+CBAUD=?
+CBAUD: (list of supported
supported
Table 3-84: +CBAUD Parameters
Description
0
Auto baud rate
1
600
2
1200
3
2400
4
4800
5
9600
6
19200
7
38400
8
57600
9
Auto baud rate
10
115200
11
300
12
230400
13
460800
The default value is 9.