beautypg.com

Mpcmc parameters -154 – PIONEERPOS AT Commands G24-LC User Manual

Page 218

background image

Hardware Information

3-154

G24-L AT Commands Reference Manual

April 15, 2008

The following table shows the +MPCMC parameters.

Example

AT+MPCMC=?

+MPCMC:(0-1)

OK

AT+MPCMC=1

OK

AT+MPCMC?

+MPCMC: 1

OK

AT+MPCMC=0

OK

AT+MPCMC?

+MPCMC: 0

OK

Command

Type

Syntax

Response/Action

Remarks

Set

+MPCMC=

OK

or:

+CME ERROR:

The Set command is used for setting
the PCM clock configuration.

Read

+MPCMC?

+MPCMC:

OK

or:

+CME ERROR:

The Read command returns the current
PCM clock value.

Test

+MPCMC=?

+MPCMC: (list of

supported s)

OK

The Test command returns the possible
values.

Table 3-99: +MPCMC Parameters

Description

0

Non-continuous PCM clock.

1

Continuous PCM clock.

Before the AT+MPCMC command is set for the first time,
this value is 0.
Power-up is according to the flex.