Example
at&v
ACTIVE PROFILE:
E1 Q0 V1 X4 &C1 &D2 &K3 &Y0
S00:000 S01:000 S02:043 S03:013 S04:010 S05:008 S06:004 S07:050
S08:004 S09:006 S10:014 S12:040 S14:AAH S16:80H S18:000 S21:30H
S22:F6H S23:1BH S25:005 S26:001 S27:09H
STORED PROFILE 0:
E1 Q0 V1 X4 &C1 &D2 &K3
S00:000 S02:043 S03:013 S04:010 S05:008 S07:050 S12:040
STORED PROFILE 1:
E1 Q0 V1 X4 &C1 &D2 &K3
S00:000 S02:043 S03:013 S04:010 S05:008 S07:050 S12:040
OK
&W, Store User Profile
The following table shows the &W parameters.
The parameters that are set in a profile are described in the table below.
Command Type
Syntax
Response/Action
Remarks
Set
&W[
OK
or:
+CME ERROR:
The Set command stores the current
active configuration to user profile 0 or
1.
Table 3-145: &W Parameters
Description
User’s profile number:
0
Store to user’s profile 0
1
Store to user’s profile 1
The default value is 0.
Table 3-146: Profile Parameters
Profile
Parameter
Description
Parameter
Range
Default
Value
Length in
Bits
ATE
Echo
0-1
1
1
ATQ
Result code return mode
0-1
0
1
ATV
Display result code
0-1
1
1
ATX
Select result code
0-4
0
3