Chapter 3: AT Commands Reference

April 15, 2008

G24-L AT Commands Reference Manual

3-195

The following table shows the different S-registers and their associated values.

Note:

S0 (Auto Answer) should work regardless of the DTR HW line state. This is a deviation
from the ITU V. 25-ter standard.

Sn

Description

Min Value

Max Value

Default Value

S0

Sets/gets number of rings before
auto answer.

0

255

0

S2

Sets/gets escape code character.

0

255

43

S3

Sets/gets carriage return code
character.

0

127

13

S4

Sets/gets line feed code character.

0

127

10

S5

Sets/gets command line editing
character (backspace).

0

127

8

S7

Sets the number of seconds in
which connection must be
established before the call is
disconnected.

1

255

30

S12

Sets/gets guard time (in units of
50 msec) for the escape character
during CSD connections

0

255

20

S14

Read-only. Holds values of En
(in bit 1),
Qn (in bit 2), Vn (in bit 3).

170

S21

Read-only. Holds values of &Dn
(in bits 2, 3 and 4), &Cn (in bits 5
and 6).

40

S22

Read-only. Holds values of Mn
(in bits 2 and 3),
Xn (in bits 4, 5 and 6)

134

S31

Read-only. Holds value of Wn (in
bits 2 and 3).

0

S36

Sets/gets value of \Nn.

0

7

5

S39

Read-only. Holds value of &Kn
(in bits 0, 1 and 2).

3

S40

Read-only. Holds value of \An
(in bits 6 and 7).

192

S41

Read-only. Holds value of %Cn
(in bits 0 and 1).

3

This manual is related to the following products: