Hardware information, Hardware information commands, Cbc, battery charger connection – PIONEERPOS AT Commands G24-LC User Manual
Page 193: Hardware information -129, Hardware information commands -129, Cbc, battery charger connection -129, Cbc parameters -129

Chapter 3: AT Commands Reference
April 15, 2008
G24-L AT Commands Reference Manual
3-129
Hardware Information
Hardware Information Commands
+CBC, Battery Charger Connection
This command enables a user to query the battery charger connection. The battery level is an
avarage value, which is updated every 30 seconds
The following table shows the +CBC parameters.
Note:
The G24-L does not allow the detection of battery use. The power supply of the G24-L is
connected via the battery pins. However, users can use this command to verify the level
of the G24-L input power source.
Example
AT+CBC
+CBC: 0,60
//This example shows 0 (battery powered) with 60% power.
Command Type
Syntax
Response/Action
Read
+CBC
+CBC:
Table 3-81: +CBC Parameters
Description
Charger detection
0
Charger not detected
1
Charger detected
Note:
The G24-L input power source is connected via the battery
pins.
Battery charge level:
VCC, V
Battery Level
>3.7
90%
3.5-3.7
60%
3.4-3.5
20%
3.35-3.4
10%
3.3-3.35
5%
<3.3
0%