Promise Technology 66 Pro User Manual
Page 29

SuperTrak66™ User's Manual
Chapter 3
- 18 -
Status
Shows one of three possible array status conditions:
Functional
The array is fully operational, and no problems are present.
Critical
The array is operational, but has lost its fault tolerance. For RAID
array levels 1, 3 and, 5 the array contains a failed drive. The user
should identify and replace the failed drive.
Offline
The array is no longer operational and the SuperBuild utility cannot
rebuild the array. The array must be rebuilt from the last tape
backup or other device. The user should identify and replace the
failed drives. For RAID levels 1, 3, and 5, at least two or more
drives in the array have failed. For a RAID 0 array, at least one
drive has failed.
Main Menu
Figure 6: SuperBuild Array Utility Main Menu
Note: This menu uses number keys 1 through 5 to select options. Many of the
subsequent menu windows use: arrow-pad keys to highlight options. Use the
spacebar to cycle through choices for the selected option. Enter (return) to select
a highlighted option. Escape to exit the menu.