beautypg.com

Kodak NOVAJET 700 User Manual

Page 81

background image

NovaJet 500/630/700 Series Service Manual

MAINTENANCE

Maintenance

3-39

The Continuous Test will first prime the cartridges,

followed by a serial port test, parallel port test, a fast

deadband display and a color calibration display.

The deadband and color calibration displays are used only

as a visual inspection of the operating condition of the

printer. No adjustments can be performed while in the

Continuous Test mode.

A loopback Test Cable is required to correctly accomplish

the serial and parallel port tests. Install both ends of the

Loopback Cable before running this test. The Loopback Test

Cable is listed in Chapter 6.

After completing the deadband display, the test will begin

again with the prime and continue until power is removed.

Fan #1 and Fan #2 Tests - Tests the operation of the fans on the

printer. Fan #1 Test (while depressed) turns on the power

supply cooling fan and the suction fan inside the platen on

the right side of the printer. Fan #2 Test (while depressed)

turns on the suction fan inside the platen near the center of

the printer. The 42 inch printer does not have this second

suction fan, therefore, the Fan #2 Test is disabled.

Legs Test - Tests the condition of the leg harness connections

and the components of the power feed and take-up system.

This manual is related to the following products: