Slide shaft cleaning, Caution – Kodak NOVAJET 700 User Manual
Page 45
NovaJet 500/630/700 Series Service Manual
MAINTENANCE
Maintenance
3-3
4. Using a cotton swab dampened with water, wipe the seals and
the rubber wiper in the service station until no more ink
residue or dust can be removed.
5. With a dry swab, wipe all moisture from the seals and wipers.
6. Close the lid and reconnect the power cord and interface cable.
7. If the service station is filling with ink or very dirty it can be
removed and rinsed under warm water. To remove, pull the
tab on the right side of the service station and lift out. Wash,
dry thoroughly and replace by placing the left side in first then
pushing down on the right side until the tab locks it in place.
Slide Shaft Cleaning
CAUTION
Use only NovaKlean™ or isopropyl alcohol on the slide
shaft of the printer. Damage to the stainless steel slide
shaft may result if cleaned with water and not completely
dried off.
Printer problems can be caused by an accumulation of dirt or other
contamination on the slide shaft. This contamination may lead to drag
on the carriage. Extreme drag results in a “carriage axis failure” fault
and will stop the carriage motion. These problems may be eliminated
by maintaining and cleaning the slide shaft at intervals determined by
the environmental conditions. Do not use any lubrication.
To clean the slide shaft:
1. Turn the printer OFF. Disconnect the power cord and
interface cable.
2. Raise the printer lid.
3. Moisten a clean cloth or paper wipe with NovaKlean™.