Remove the media take-up and feed motors – Kodak NOVAJET 700 User Manual

Page 164

background image

5-52

Assembly\Disassembly

NovaJet 500/630/700 Series Service Manual

Install the Media Take-Up and Feed Sensor

Brackets and Sensors

1. Using a #2 Phillips screwdriver, install the two screws securing the

bracket to the leg assembly.

2. Insert the sensor into the hole on the sensor bracket, secure by

screwing on the plastic nut onto the front of the sensor.

3. Route the sensor wires to the back of the bracket and secure the

wires using two wire tie wraps.

4. Bringing the wire from under the bracket, attach the wire

connector to the leg harness plug. Push connector in until firmly

seated.

Remove the Media Take-Up and Feed Motors

1. Remove all media and media rollers from the printer.

2. Remove the four screws holding the Cradle Idler to the leg

assembly. See Figure 5-29.

3. Carefully slide the Cradle Idler assembly out of the leg assembly

until the wires going to the motor can be removed.

4. Remove the wires from the motor.

5. From the back of the Cradle Idler, disconnect the tension spring

from the post located on the Cradle Idler.

6. Using a #2 Phillips screwdriver, remove the screw and washer

holding the motor mount to the Cradle Idler. Carefully remove the

motor, motor mount, and motor gear subassembly from the Cradle

Idler.

7. Remove the C clamp that is securing the motor gear to the motor.

8. Using a #1 Phillips screwdriver, remove the three screws, washers,

and lock washers from the motor mount to remove the motor.