NovaJet 500/630/700 Series Service Manual

MAINTENANCE

Maintenance

3-23

3. Place the test cartridge upright on a flat surface and ‘zero’ the

gauge by loosening the knob near the top and turning the dial

until the needle is at the ‘0’ position on the dial. Tighten the

knob. See Figure 3-16.

ZERO

GAUGE

ENSURE PRESSURE IS
PLACED ON THE REAR
OF THE CARTRIDGE

0

Figure 3-16. Zeroing the Micrometer Gauge.

4. Remove the Cyan ink cartridge. Snap the test cartridge with

the micrometer gauge into the position vacated by the Cyan

ink cartridge. See Figure 3-17. Ensure that the micrometer

can be read from the BACK of the printer.

Figure 3-17. Test Cartridge Installed.