3-30

Maintenance

NovaJet 500/630/700 Series Service Manual

Allowable values for the Deadband calibration on the 500 series printers

is from 0 to 120.

The deadband test on a NovaJet 630 or 700 series printer will print a

display similiar to Figure 3-22 but will print the pattern for each of the

four colors. This is just a visual check of the color deadband alignment.

No adjustments can be made for this test. To make adjustments, if

needed, see the Color Deadband Calibration section.

Allowable values for the Color Deadband calibrations on the 630/700

series printers is from 0 to 120 but the actual value used by the printer

will only accept certain numbers. The real value used by the printer

will be the closest of 12, 20, 28, 36, 44, 52, 60, 68, 76, 84, 92 or 100.

To perform the Slow Deadband Alignment

1. Select “Utility Menu” from the Main Menu. This brings up the

Utility Menu as shown in Figure 3-19.

2. Select the “Service Menu” from the Utility Menu. This brings

up the Service Menu as shown in Figure 3-23.

Calibration Menu

Diagnostics Menu

About

Cartridge Info.

Test Print

Exit

*

Figure 3-24. Service Menu.

3. Select the “Calibration Menu” from the Service Menu.

4. The Calibration Menu is shown in Figure 3-24 for the 500 series

and Figure 3-25 for the 630/700 series and is where the

deadband tests are performed. Select “Slow Db Test” to run the

slow deadband test.