NovaJet 500/630/700 Series Service Manual

MAINTENANCE

Maintenance

3-25

CAUTION

Use extreme care when performing this

calibration on the NovaJet 505 printers.

The actual head height that is to be

achieved is 0.125” +/- 0.003”. The read-

ing will only be correct if the gage rotated

one complete turn before stopping at 17.

If the head is adjusted for 0.025” instead

of 0.125” head strikes and quality issues

will be apparent.

NOTE

The actual measurement is different than the true head

height due to the fact that the test cartridge does not con-

tain a jet plate assembly. A difference had to be calcu-

lated to compensate for the lack of a jet plate assembly on

the test cartridge.

9. Tighten the screw on the left side of the stabilizer.

10. While lifting up the measuring tip of the micrometer, slide the

Carriage to the right until the next stabilizer screw is lined up.

Position it as close to the screw as possible and drop the

measuring tip onto the platen. Do this a couple of times to

ensure an accurate reading.

11. Move the left end of the stabilizer bracket until a correct

reading is observed. Read only the RED numbers on the

micrometer gauge.

12. Tighten the screw on the stabilizer that is next to the Carriage.

13. Continue performing steps 10 through 12 until all four of the

stabilizer screws have been adjusted.