3.5.4.4 Installing an SBus Card

1. Use the procedures in Section 3.5.2, “Removing a Board,” to

remove the applicable I/O board.

2. Use Figure 3-13 to locate the SBus connector for the card that is to be

installed.

3. If a filler panel covers the back panel SBus slot, remove the two screws

and detach the filler panel.
Retain the screws to attach the SBus card to the back panel, unless the card
has a wide connector, or set of connectors.

4. Unlock the tip insert of the two standoffs for the SBus slot.

See Figure 3-14.

5. Attach a wrist strap and take the SBus card out of the protective

packaging. Inspect the pins in the connector to make sure they are not
bent.

6. Hold the SBus card at an angle and guide the SBus card face plate under

the springfingers and against the rear face of the I/O board front panel.
See Figure 3-15 on page 3-22. The I/O connectors of the SBus card should be
visible through the opening in the back panel.

7. Hold the card by the edges nearest the SBus connector and place the card

over the two standoffs.

8. Hold the SBus card by the edges near the connector and firmly but gently

press the card down until the connector is fully seated.
To align the connector and socket, push the card toward the I/O board back
panel.

Disabled

Enabled

2

1

2