beautypg.com

5 defective disk board, Figure105 diagnosing disk board problems, 5 defective disk board -6 – Sun Microsystems 6.0005E+11 User Manual

Page 180: Figure 10-5, Diagnosing disk board problems, Defective disk board

background image

10-6

Ultra Enterprise 6000/5000/4000 Systems ManualNovember 1996

10

10.5 Defective Disk Board

The disk board is hot-pluggable.

Figure 10-5 Diagnosing Disk Board Problems

INDICATION

System error message or

LED code identifies a
specific board

Board not identified or

intermittent problem

Begin

End

TEST/PROCEDURE

Locate indicated board.
Check LEDs on board to verify ASR

has deactivated the board.

Set the SCSI IDs of the

replacement drives.

Replace the board or device.
Board is not active until system is

booted.

Check

/var/adm/messages

Locate defective SCSI device with

probe-scsi-all

(OpenBoot

command).

Check ID jumpers on board

REFERENCE

LED code must be Off-On-Off. See

Table 9-2.

See Appendix C, “SCSI Devices.

See Section 3.3, “Hot-Plug Feature.

Section C.2, “Disk Board Target IDs.