Table92 board status led codes, Table 9-2, Board status led codes – Sun Microsystems 6.0005E+11 User Manual
Page 164
9-4
Ultra Enterprise 6000/5000/4000 Systems Manual—November 1996
9
Caution – If the left green LED is lit, do not remove the board. Electrical
shorting will result, damaging the board and the system.
For the CPU/Memory and I/O boards:
•
If the yellow LED (middle LED) is continuously lit (not flashing) the board
requires service.
•
If the left and right green LEDs are off, the board is ready for removal.
•
If no LEDs are flashing, the system is hung.
•
If no LEDs are lit, there is no electrical power to the board.
Table 9-2 summarizes LED codes for these boards. The symbols shown in the
table are marked on the card cage frame.
Table 9-2
Board Status LED Codes
Power
Service
Cycling
Condition
Off
Off
Off
Board has no electrical power.
Off
On
Off
Board is in low power mode, can be unplugged.
Off
Off
Flashing
Undefined.
Off
On
Flashing
Undefined.
On
Off
Off
System is hanging, either in POST/OBP or OS.
On
Off
On
Hung in OS.
On
On
Off
(Hung in POST/OBP) or (hung in OS and failed
component on board).
On
On
On
(Hung in POST/OBP) or (hung in OS and failed
component on board).
On
Off
Flashing
OS running. System is operating normally.
On
On
Flashing
OS running and failed component on board.
On
Flash
Off
Slow flash = POST. Fast flash = OBP.
On
Flash
On
OS or OBP error.
!