Ultra Enterprise 6000/5000/4000 Systems ManualNovember 1996

9

Caution – If the left green LED is lit, do not remove the board. Electrical
shorting will result, damaging the board and the system.

For the CPU/Memory and I/O boards:

If the yellow LED (middle LED) is continuously lit (not flashing) the board
requires service.

If the left and right green LEDs are off, the board is ready for removal.

If no LEDs are flashing, the system is hung.

If no LEDs are lit, there is no electrical power to the board.

Table 9-2 summarizes LED codes for these boards. The symbols shown in the
table are marked on the card cage frame.

Table 9-2

Board Status LED Codes

Power

Service

Cycling

Condition

Off

Off

Off

Board has no electrical power.

Off

On

Off

Board is in low power mode, can be unplugged.

Off

Off

Flashing

Undefined.

Off

On

Flashing

Undefined.

On

Off

Off

System is hanging, either in POST/OBP or OS.

On

Off

On

Hung in OS.

On

On

Off

(Hung in POST/OBP) or (hung in OS and failed
component on board).

On

On

On

(Hung in POST/OBP) or (hung in OS and failed
component on board).

On

Off

Flashing

OS running. System is operating normally.

On

On

Flashing

OS running and failed component on board.

On

Flash

Off

Slow flash = POST. Fast flash = OBP.

On

Flash

On

OS or OBP error.

!