beautypg.com

Table61 power supply summary, 1 safety precautions, Table62 safety precautions – Sun Microsystems 6.0005E+11 User Manual

Page 134: Table 7-1, Power supply summary, Table 7-2, Safety precautions

background image

6-2

Ultra Enterprise 6000/5000/4000 Systems ManualNovember 1996

6

Note – A functioning peripheral power supply provides electrical precharge
that is required for the hot-plug feature. Use the

prtdiag (1M)

command to

determine if electrical precharge is available.

Table 6-1 lists the power supply voltages, their uses, and the power supplies
that generate them.

6.1 Safety Precautions

To protect both yourself and the equipment, any servicing of equipment
should be performed by qualified personnel. Observe the precautions in
Table 6-2.

Table 6-1

Power Supply Summary

Voltage

Supply

Use

2.0V

PCM

GTL centerplane termination

3.3V

PCM

CPU/Memory Board (AC, DCs, FHC, SIMMs)
UltraSPARC Module (SRAMs, SDBs, CPU I/O)

5V

PCM, PPS

SBus, Clock Board
UltraSPARC Module power (via DC/DC converter)

12V

PPS

Peripherals (CD drive, tape drive)

Table 6-2

Safety Precautions

Item

Problem

Precaution

Wrist or
foot strap

ESD

Wear a conductive wrist strap or foot strap when handling power supplies.

ESD mat

ESD

An approved ESD mat provides protection from static damage when used
with a wrist strap or foot strap.

Cover panels

System damage
and overheating

Re-install all cabinet cover panels after performing any service work on the
system.

SBus slot covers

System damage
and overheating

Install SBus slot covers in all unused SBus slots.