Table61 power supply summary, 1 safety precautions, Table62 safety precautions – Sun Microsystems 6.0005E+11 User Manual
Page 134: Table 7-1, Power supply summary, Table 7-2, Safety precautions
6-2
Ultra Enterprise 6000/5000/4000 Systems Manual—November 1996
6
Note – A functioning peripheral power supply provides electrical precharge
that is required for the hot-plug feature. Use the
prtdiag (1M)
command to
determine if electrical precharge is available.
Table 6-1 lists the power supply voltages, their uses, and the power supplies
that generate them.
6.1 Safety Precautions
To protect both yourself and the equipment, any servicing of equipment
should be performed by qualified personnel. Observe the precautions in
Table 6-2.
Table 6-1
Power Supply Summary
Voltage
Supply
Use
2.0V
PCM
GTL centerplane termination
3.3V
PCM
CPU/Memory Board (AC, DCs, FHC, SIMMs)
UltraSPARC Module (SRAMs, SDBs, CPU I/O)
5V
PCM, PPS
SBus, Clock Board
UltraSPARC Module power (via DC/DC converter)
12V
PPS
Peripherals (CD drive, tape drive)
Table 6-2
Safety Precautions
Item
Problem
Precaution
Wrist or
foot strap
ESD
Wear a conductive wrist strap or foot strap when handling power supplies.
ESD mat
ESD
An approved ESD mat provides protection from static damage when used
with a wrist strap or foot strap.
Cover panels
System damage
and overheating
Re-install all cabinet cover panels after performing any service work on the
system.
SBus slot covers
System damage
and overheating
Install SBus slot covers in all unused SBus slots.