beautypg.com

6 defective disk drive, Figure106 diagnosing disk drive problems, 6 defective disk drive -7 – Sun Microsystems 6.0005E+11 User Manual

Page 181: Figure 10-6, Diagnosing disk drive problems, Defective disk drive

background image

Flow Diagrams for Troubleshooting

10-7

10

10.6 Defective Disk Drive

Figure 10-6 Diagnosing Disk Drive Problems

INDICATION

System error message or

device code identifies a
specific fault

Device not identified or

intermittent problem

Begin

End

TEST/PROCEDURE

Check

/var/adm/messages

Halt access to device and power

down the device or tray.

Set ID code (if used) on

replacement device before
installing.

If replaced unit is SPARCstorage

Array disk tray or the tray
controller board, reset
world-wide name (WWN).

Run SunVTS.
For SCSI device, use OpenBoot

probe-scsi-all

.

Check cable connection.
If replaced unit is SPARCstorage

Array disk tray or the tray
controller board, reset
world-wide name (WWN)

REFERENCE

Internal drives: Chapter 6, “Clock

Board. “

Tray: see tray service manual.
Refer to drive or tray documentation for

ID code.

Refer to SPARCstorage Array

documentation.

Refer to

SunVTS User’s Guide.