Recording camera images, Recording modes, Recording operation during power failure – JVC VR-N1600E User Manual
Page 56: Recording

48
Recording Modes
Ⅵ Recording Control Mode (A Page 49)
This mode performs recording according to the [Camera Record
Setting].
The [REC CONTROL] indicator lights up.
You can switch the recording control mode on or off by pressing and
holding the [REC CONTROL] button.
● Set each camera to on/off using the [Scheduler...] settings
● Specify the frame rate and conditions for starting recording in
[Camera Settings](A Page 51).
Note :
● During the interval that is set as offline in [Scheduler...],
recording will not be performed regardless of the [Camera
Settings].
● The [REC CONTROL] button is AdisabledB when the main menu
is displayed, when settings are being specified, and during
recording.
● When there is an unconnected camera, it may take a while
before the [REC CONTROL] indicator lights up.
Memo :
● Press the [REC/STOP] button to cancel the Arecording control
mode
B and enable manual recording mode.
● Press and hold down the [REC/STOP] button to cancel all
Arecording modesB and stop recording.
● Setting [Operate] to ON switches the mode automatically to the
Arecording control modeB. (When the AON at startupB checkbox
of [Record Control] under [Unit Setting] of the main menu is
selected. )
Ⅵ Manual Recording Mode
The manual recording mode executes recording from all cameras
regardless of the [Camera Record Setting]. Recording is executed
in the frame rate specified in [Recording Settings]-[Desired
framerate] of the [Camera Settings] screen.
Manual recording lets you start and stop recording on all cameras
by using the [REC/STOP] button. Press the [REC/STOP] button to
start recording. Press and hold down the [REC/STOP] button to
stop recording.
The [REC CONTROL] indicator lights up.
Ⅵ [EXT REC IN] Signal Recording Mode
Recording starts on all cameras when the [EXT REC IN] terminal of
the rear input/output terminal is set to MAKE. Recording is
executed in the frame rate specified in [Recording Settings]-
[Desired framerate] of the [Camera Settings] screen.
Recording using [EXT REC IN] signals has priority over the
recording control mode or manual recording.
When recording by the [EXT REC IN] signals is complete, the
cameras return to the original recording mode.
Memo :
● When recording using signals from the [EXT REC IN] terminal,
the light of the [REC CONTROL] indicator goes off, and the
[REC] indicator appears blinking.
● Emergency recording lets you start and stop recording on all
cameras regardless of the [Scheduler...] settings or [Camera
Settings].
● Pressing the [REC/STOP] button cancels recording by signals
from the [EXT REC IN] terminal and switches automatically to
the
Amanual recording modeB. The [REC] indicator also
changes from
AblinkingB to the AlitB mode.
● Pressing and holding down the [REC/STOP] button cancels
recording by signals from the [EXT REC IN] terminal and stops
recording.
Ⅵ Emergency Recording Mode
Recording starts on all cameras when a MAKE signal is detected by
the [EMERGENCY] terminal of the rear input/output terminal.
Recording is executed in the frame rate specified in [Recording
Settings]-[Desired framerate] of the [Camera Settings] screen.
Recording is only executed during the time specified in [Emergency
Record] of [Unit Setting](A Page 66).
Emergency recording has priority over the [recording control mode]
or [manual recording] mode.
When emergency recording is complete, the cameras return to the
original recording mode.
Memo :
● The [REC CONTROL] indicator goes off and the [REC] indicator
appears blinking during emergency recording.
● Emergency recording lets you start and stop recording on all
cameras regardless of the [Scheduler...] settings or [Camera
Settings].
● Pressing the [REC/STOP] button cancels emergency recording
and switches automatically to the
Amanual recording modeB.
The [REC] indicator also changes from
AblinkingB to the AlitB
mode.
● Press and hold down the [REC/STOP] button to cancel all
recording modes and stop recording.
Note :
● When in the manual recording, [EXT REC IN] signal recording or
emergency recording mode, motion detection and event
recording settings are ignored.
Recording Operation During Power Failure
If a power failure occurs during recording, the system resumes
recording in the mode selected before the power failure after
recovery.
● In the recording control mode, recording by a motion or event
does not resume unless another motion or event occurs after
recovery from the power failure.
● The recording control mode returns to the status before the
power failure.
Note :
● The recorded images may not be played back properly if they
are not archived (A Page 104) before the power failure.
● It is recommended that an uninterruptible power supply (UPS)
be used to protect the hard disk from damage in the event of a
power failure. (A Page 128)
● When a power failure occurs while formatting a hard disk or
archiving, subsequent operation may be affected even when an
UPS is connected.
Recording Camera Images
There are four different recording modes.
● Recording Control Mode
● Manual Recording Mode
● EXT REC IN Signal Recording Mode
● Emergency Recording Mode
VR-N1600_J.book Page 48 Tuesday, June 3, 2008 2:26 PM