Chapter 6 - Hardware Reference

6-6

Using IDC Position Sensors as EOT Limit Switches with the Impulse

Four IDC position sensors may be used as EOT limit switches with the Impulse. Connection
information for all four sensors is provided below.

+5V

COM

COM

N.C. Reed Switch

RPS-2
Only

INPUT

external

Impulse internal

external

Impulse internal

external

Impulse internal

The PSR-2 position sensor is a nor-
mally closed Reed Switch and must be
connected to two (2) separate inputs, as
shown here. This leaves two (2) inputs
for move selects, which allows for the
selection of three (3) stored moves.

The PSR-2 position sensor contains a
series diode and cannot be used in
series, as is the RPS-2 sensor shown
below

.

Note: If you need to configure more
than 3 stored moves, the position sen-
sors below only require one input for
connection.

+5V

COM

COM

RPS-1

or

PSR-1

N.O. Reed Switch

INPUT

The RPS-2 position sensor is a nor-
mally closed Reed Switch and must be
connected in series as shown here.

The RPS-1 or PSR-1 position sensors
are normally open Reed Switches and
must be connected in parallel as shown
here.

+5V

COM

COM

PSR-2
Only

N.C. Reed Switch

INPUT

+5V

INPUT

INPUT

INPUT

PSR-2

RPS-2

RPS-1

PSR-1