beautypg.com

Filling empty drive bays, Configuring your onboard raid solutions, Configuring the onboard scsi raid solution – Gateway 9415 User Manual

Page 67

background image

62

www.gateway.com

Filling empty drive bays

Empty drive bays in the server must be filled by empty drive carriers or empty drive trays,
as appropriate. With the bezel removed, install the appropriate carrier, then replace the
bezel by snapping it into place on the front of the server. Empty drive carriers for unused
drive bays are included with your server.

Configuring your onboard RAID solutions

Your server comes equipped with an onboard, chipset SCSI RAID solution, which supports
RAID levels 0 (striping) and 1 (mirroring). The onboard RAID solutions can be enabled in
the BIOS (

page 154

) and configured by launching the appropriate RAID BIOS console

during the boot process.

Configuring the onboard SCSI RAID solution

To launch the SCSI RAID BIOS console:

1

Restart your server.

2

Press F2 when the Gateway logo screen appears during startup. The BIOS Setup utility
opens.

3

From the

Main

BIOS menu, select the

Advanced

menu.

4

Select the

PCI Configuration

sub-menu.

5

For the

Onboard SCSI

option, click

Enabled

.

6

Exit the BIOS Setup utility.

7

Restart your server.

Level

Description and use

Pros

Cons

Number
of drives

Fault
Tolerant

0

Data divided into blocks and
distributed sequentially (pure
striping). Use for non-critical data
that requires high performance

High data
throughput for
large files

No fault tolerance.
Data is lost if a drive
fails.

One or
two

No

1

Data duplicated on another disk
(mirroring). Use for
read-intensive, fault-tolerant
systems.

100 percent
data
redundancy,
providing fault
tolerance.

More disk space
required. Reduces
usable disk space
to the size of the
smallest drive.
Reduced
performance during
rebuilds.

Two

Yes

8510522.book Page 62 Wednesday, March 16, 2005 11:19 AM