Updating the fru/sdr – Gateway 9415 User Manual
Page 42
37
www.gateway.com
12
Remove the PCI riser assembly.
13
Move the shorting block on the Boot Block jumper (J1B1) back to pins 2-3.
14
Replace the PCI riser assembly.
15
Follow the instructions in
“Closing the server case” on page 44
.
Updating the FRU/SDR
The FRU/SDR must be updated whenever you add additional hardware to your server
that must be monitored by the BMC. This includes adding a redundant power supply
module, adding redundant hot-swap fans, or adding an Intel Management Module
(IMM). The FRU/SDR must also be updated whenever you update the BIOS.
Each time you update the FRU/SDR, we recommend that you check
support.gateway.com
for the most current version of the utility. If a newer version is
available than the one included on the SCCD, download the newer version and use
it instead of the SCCD in the following procedure.
To update the FRU/SDR:
1
Boot your server to DOS (using a DOS-bootable diskette, CD, or USB disk on key).
2
Put the System Companion CD in the CD drive and change directories (to the CD drive)
to access it.
3
When the System Companion CD menu opens, select the FRU/SDR utility.
4
Select one of the following options (if in doubt, choose the second option and update
both):
Update just the SDR repository - Select this option when sensor information needs
to be changed (for example, if the CPU is upgraded to a higher speed or if memory
is replaced).
-OR-
Update the FRUs and the SDR repository (and mBMC TBLs - if the IMM module is
not present) - Select this option if have installed additional hardware (for example,
a redundant power supply or system fans, or additional memory).
5
When you are asked if you have an optional cooling kit installed, type Y if your system
has redundant fans installed or N if you system has only the basic fans installed.
6
Exit the utility, remove the System Companion CD, and reboot your server.