Additional beep codes provided by optional Intel
Management Modules

In addition to the preceding beep codes, the following additional beep codes are provided
if an Intel Management Module is installed:

LED information

The system board in this server includes LEDs that can assist you in troubleshooting your
system. See the following table for a description of these LEDs and the information they
provide:

Beep Codes

Description

1

Control panel CMOS clear has been initiated

1-5-1-1

Processor failure. Reseat or replace the failed processor.

1-5-2-1

No processor is installed or the CPU 1 socket is empty.
Reseat or replace the failed processor.

1-5-2-3

Processor configuration error or CPU 1 socket is empty.
Reseat or replace the failed processor. In a
two-processor system, make sure the processors are
identical.

1-5-2-4

Front-side bus select configuration error.

1-5-4-2

DC power unexpectedly lost.

1-5-4-3

Chipset control failure.

1-5-4-4

Power control failure.

LED Name

Function

Location

Color

Description

ID

Aid in server
identification

Front panel and
left back of
system board

Blue

On = Server identification
enabled

System Fault

Visible fault
warning

Front panel and
left back of
system board

Green or
Orange

On = No fault

Green blink = Degraded

Orange = Critical error or
non-recoverable

Orange blink = Non critical

ATA drive
activity

Indicate drive
activity

Front panel and
left side of
system board

Green

Blinking = Drive active