24 operating manual, Technical data preface – FUJITSU PRIMERGY RX600 S5 User Manual
Page 24

24
Operating Manual
RX600
S5
Technical data
Preface
©
c
ogn
it
as
.
G
e
s
e
lls
c
h
ft
f
ü
r T
e
c
h
ni
k
-D
o
k
u
m
e
n
tat
ion m
b
H
20
10
P
fa
d
:
C
:\
P
rogra
m
m
e
\F
CT
\t
im
_a
pp
\t
im
_l
o
c
a
l\
w
or
k
\P
ICH
OL
\O
B
J
_
D
O
K
U
-4
8
8
4
-0
03
.f
m
Dimensions / Weight
Ventilation clearance
At least 200 mm on the front and rear.
Ambient conditions
Condensation during operation must be avoided!
Noise level
Rack (W x D x H)
482.6 mm (Bezel) / 444.8 mm (Body) x 770.0 mm x
176.0 mm
Mounting depth rack
728 mm
Height unit rack
4 U
19" rackmount
Yes
Mounting cable depth
rack
100 mm (1000 mm rack recommended)
Weight
min. 32 kg; max. 46 kg (actual weight may vary
depending on configuration)
Rack integration kit
rack integration kit as option
I
Rack integration kit is standard for the
japanese market.
Environment class 3K2
Environment class 2K2
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
Temperature:
Operation (3K2)
10 °C .... 35 °C
Transport (2K2)
-25 °C .... 60 °C
Humidity
10% ... 85% (non condensing)
Sound power level L
WAd
(ISO 9296)
< 6.2 B (standby)
< 6.6 B (operation)
Sound pressure level at bystander position L
pAm
(ISO 9296) (at < 23 °C)
< 46 dB(A) (standby)
< 51 dB(A) (operation)