Alvarion BREEZEACCESS SW VERSION 5.1 User Manual
Page 227

Menus and Parameters
Operation and Administration
195
The actual value will be the entered value rounded to the nearest multiple of 128
(N*128).
4.2.6.6.2.2 MIR:
Uplink (SU only)
Sets the Maximum Information Rate of the up-link from the SU to the AU. The
MIR value cannot be lower than the corresponding CIR value.
Available values range and default value are shown in Table 4-14.
The actual value will be the entered value rounded to the nearest multiple of 128
(N*128).
4.2.6.6.2.3 CIR:
Downlink (SU only)
Sets the Committed Information Rate of the downlink from the AU to the SU. The
CIR value cannot be higher than the corresponding MIR value.
Available values range and default value are shown in Table 4-15.
The actual value will be the entered value rounded to the nearest multiple of 128
(N*128).
4.2.6.6.2.4 CIR:
Uplink (SU only)
Sets the Committed Information Rate of the uplink from the SU to the AU. The
CIR value cannot be higher than the corresponding MIR value.
Available values range and default value are shown in Table 4-15.
The actual value will be the entered value rounded to the nearest multiple of 128
(N*128).
Table 4-14: MIR Ranges and Defaults
MIR Uplink
MIR Downlink
Unit
Type
Range (Kbps)
Default (Kbps)
Range (Kbps)
Default (Kbps)
SU-3 128-2,048 2,048
128-3,072
3,072
SU-6 128-4,096 4,096
128-6,016
6,016
SU-8 128-13,440 13,440
128-13,440
13,440
SU-54 128-53,888 53,888
128-53,888
53,888
SU-I 128-4,096 4,096
128-6,016
6,016