Chapter 4 - Operation and Administration

BreezeACCESS VL System Manual

104

The parameters configured in the unit are not changed as a result of loading new
software versions unless the new version includes additional parameters or
additional changes in the list of parameters. New parameters are loaded with
their default values.

Select from the following options:

„

Reset and Boot from Shadow Version: Activates the shadow (backup)

software version. The unit is reset automatically. Following the next reset the
unit will switch to the main version.

„

Use Running Version After Reset: Defines the current running version as

the new main version. This version will also be used following the next reset.

4.2.3.6 Log

Out

Timer

The Log Out Timer parameter determines the amount of inactive time following
which the unit automatically exits the Monitor program.

The time out duration can range from 1 to 999 minutes.

The default value is 5 minutes.

4.2.3.7

Ethernet Negotiation Mode

The Ethernet Port Negotiation Mode submenu displays the current Ethernet port
state and enables defining the negotiation mode of the Ethernet port. The
available options are:

„

Force 10 Mbps and Half-Duplex

„

Force 10 Mbps and Full-Duplex

„

Force 100 Mbps and Half-Duplex

„

Force 100 Mbps and Full-Duplex

„

Auto Negotiation (10/100 Mbps and Half/Full Duplex)

The default is Auto Negotiation (10/100 Mbps and Half/Full Duplex)

4.2.3.8 Change

System

Location

The Change System Location option enables changing the system location of the
unit, which is also the sys location in MIB2. The System Location is also
displayed as a part of the Monitor menu’s header.

Valid values: A string of up to 35 printable ASCII characters.