Applications

286

IDEC SmartRelay Manual

8.5.1

Requirements for a gate control system

• Every gate is opened and closed by means of a

cord-operated switch. The gate is will be fully opened or

fully closed.

• All gate can be opened and closed locally by means of

pushbuttons.

• The gate can be opened and closed at the gatehouse by

means of the bus system. The GATE OPEN or GATE

CLOSED status is indicated.

• An indicator lamp is switched on five seconds before the

gate starts moving and when the gate is in motion.

• A safety pressure bar prevents harm to persons and

objects from getting trapped or damaged when the gate

closes.

Wiring of the gate control system with FL1E-H12RCC and CM AS-

Interface

N

L1

N

I3

I4

I5

I6

I7

I8

K1

K2

L1

S0

S1

S2

S3

S4

S5

S6

p>

S6

p >

I2

I1

Q1

Q2

Q3

Q4

1 2

1 2

1 2

1 2

Gate

Gate

Indicator lamp

AS-Interface