beautypg.com

Applications, Idec smartrelay manual 283 – IDEC FL1E SmartRelay User Manual

Page 297

background image

Applications

IDEC SmartRelay Manual

283

Components used

• K1

contactor relay

• K2

contactor relay

• S0 (normally closed contact) STOP pushbutton
• S1 (normally open contact)

OPEN pushbutton

• S2 (normally open contact)

CLOSE pushbutton

• S3 (normally closed contact) Position sensor OPEN
• S4 (normally closed contact) Position sensor CLOSED
• S5 (normally closed contact) Safety bar

Block diagram of the IDEC SmartRelay solution

The OPEN or CLOSE pushbuttons initiate the gate motion,

provided it is not already moving in the other direction. The

gate is stopped by means of the STOP pushbutton or the

relevant limit switch. A safety bar furthermore interrupts the

closing motion of the gate.

T=
5 s

T=
5 s

x

x

x

x

Q1

Q3

Q2

I3

I4

I3

I6

I5

I1

I2

Q2

Q1

T

H

=

T

L

=2 s

Inv=lo

I2

I1

Start push-
button
CLOSED

Start push-
button OPEN

STOP push-
button
Gate is open

CLOSE push-
button

CLOSE pushbutton

OPEN pushbutton

STOP pushbutton
Safety bar
Gate is closed

Open

Signal
lamp

Close