beautypg.com

Hyundai HI4 User Manual

Page 247

background image

6. System setting

------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------

6 - 83

6.4.2 Arc

Outline

It sets a function to do the arc welding.

Please refer to the "Operation manual on the HR controller" for the precise contents.

Screen display

Reference

„ The arc condition parameter is taken in custody in the control constant file

(ROBOT.C00).

„ It can be changed in case that the control constant file (ROBOT.C00) is completely

taken in custody.

6.4.2.1 Condition parameter

Outline

It sets a variety of condition for the welding work in the arc welding.

Screen display

14:39:38 *** Arc Weld *** A:0 S:4

1: Condition Parameter






Use [Number]/[Up][Down] and press [SET].

>

Previous

Next

14:39:38 ** Arc Weld ** A:0 S:4

1: Fast step Go/Back = Max.speed*[

1

]%

2: Inching Spd: Slow=[ 1]%,Fast=[ 1]%
3: Assign Welding Current Port =[ 0]
4: Assign Welding Voltage Port =[ 0]
5: Assign [ARC On] state output =[ 0]
6: Welder error input =<

DSBL

,ENBL>

7: Welding wire state =<

DSBL

,ENBL>

8: Shield Gas state =<

DSBL

,ENBL>

9: Feeder Ty=(Motor & Dir.)=<

DSBL

,ENBL>

10: Gas Postflow at weld stop =[ 0.0]sec

Enter number and press [SET]

>[1 - 25]