beautypg.com

Eliminate crosstalk between drum triggers, Crosstalk cancellation), Tips for positioning the drum triggers – Roland TM-6 Pro Drum Trigger Module User Manual

Page 18: Trigger settings (trig)

background image

18

Trigger Settings (TRIG)

Eliminate Crosstalk Between Drum Triggers

(Crosstalk Cancellation)

If two drum triggers are attached to the same stand, the

vibration from one struck drum trigger may cause the other

drum trigger to sound without your intention. This is called

“crosstalk.” Crosstalk cancellation is a setting that prevents

this type of crosstalk.

* In some cases, the acoustic sound from an acoustic drum

or from a monitor speaker might cause a drum trigger

to be triggered. In such cases, adjusting the crosstalk

cancelation settings will not solve the problem. Pay

attention to the following considerations when setting

up your equipment.

5

Set up the drum triggers at a distance from the

speakers

5

Angle the drum triggers, placing them where they are

less likely to be affected by the sound

5

Increase the Threshold value of the drum trigger

(p. 16)

Tips for positioning the drum triggers

You can prevent crosstalk by positioning the drum

triggers in a way that minimizes their susceptibility to

an external source of vibration.
Before you adjust the crosstalk cancellation settings,

please note the following points when setting up your

system.

5

Don’t place drum triggers in contact with each

other.

5

If attaching multiple drum triggers to the same

stand,increase the distance between them.

5

Firmly tighten the knobs that fasten the drum

trigger to ensure that the drum trigger is securely

attached to the stand.

Example) If the sound of trigger input 2 is

heard when you strike the drum trigger of

trigger input 1

1

In the TRIGGER SETUP screen (p. 14), select

“XTALK” and press the [ENTER] button.

The XTALK MONITOR screen appears.

Trigger input number

Crosstalk cancellation settings

2

Strike the drum trigger of trigger input 1.

The crosstalk detection status is shown in the XTALK

MONITOR screen.
The illustration below shows that when you struck

the drum trigger of trigger input 1 (TRIG 1), the drum

triggers of trigger input 2 (TRIG 2) and trigger input 3

(TRIG 3) detected the vibration.
A “

H

” symbol is shown for drum triggers that are

experiencing crosstalk.

Crosstalk occurring

Drum triggers

detecting vibration

Explanation

Trigger input 2

(TRIG 2)

Crosstalk is occurring.
By adjusting the crosstalk

cancellation value, you can

prevent the sound from being

triggered.

Trigger input 3

(TRIG 3)

Will not sound, because

crosstalk cancellation is active.

3

Press the [F2] (FOCUS) button to move the

cursor to TRIG 2.

If crosstalk is occurring for multiple drum triggers, each

press of the [F2] (FOCUS) button will move the cursor to

another drum trigger that is experiencing crosstalk.