Operating Instructions Powador XP500/550-OD-TL
U s e r i n t e r f a c e
9.3.3 Wind speed sensor
Black (bk)
Brown (bn)
GND
Wind speed (0~10V)
bk bn
1c
1c
1d
1d
2c
2c
2d
2d
UA
I
3c
3c
3d
3d
4c
4c
4d
4d
Figure 82: Wind speed sensor
Figure 83: Confi guration of the wind speed sensor
Terminal number
Terminal designation
Specifi cation
Wire cross- section
3c
PTP
0 to 10V
AWG 24
(0.205mm
2
)
3d
PTN
4c
RSVP
0 to 10V
4d
RSVN
Table 29: Connections for analogue user input - PT 1000 ambient temperature sensor, wind speed sensor
9.3.4 Parameter settings for analogue sensors
IIn order to determine measured values using the analogue sensors, you have to set the “Options” parameter.
The options are calculated and set by a service technician from KACO new energy Inc.,.
ATTENTION
Be careful not to destroy the sensor's measuring input!
Avoid using voltages > 10V and make sure that the polarity is correct.